PROGRAM MODES
Mode No.
Fusing
Temperature
Adjustment
49
Fusing Ready
Temperature
Adjustment
50
Exposure
Lamp Voltage
Display
51
Fusing
Temperature
52
Display =
TD Sensor
Target Control
53
Voltage
Adjustment
TD Sensor
Gain
54
Adjustment
TD Sensor
Output Display
Data =
55
ADS
Reference
56
Voltage
Adjustment
ADS Output
Voltage
57
Display =
A219
CÓPIA NÃO CONTROLADA
Function
Adjusts the control temperature of the hot roller
during copying in 1°C steps.
Adjusts the ready temperature of the hot roller
during the warm-up period in 1°C steps.
Normally, this value should not be changed.
Displays the current exposure lamp voltage.
For 120 V machines, the actual applied
voltage = displayed value/2
The exposure lamp turns on for 10 seconds when
this mode is selected. Do not repeat more than 5
times, to avoid overheating the optics cavity.
Displays the fusing temperature detected by the
fusing thermistor.
Press the ! key to monitor the temperature
during the normal copy cycle.
If the setting of SP30 (Toner Supply Mode
Selection) is 1 or 3, this value is used for the TD
sensor target voltage.
Normally, this value should not be changed.
When the TD Sensor initial setting is performed, this
mode is adjusted automatically.
Normally, this value should not be changed.
Displays the TD sensor output voltage.
Press the ! key to monitor the output voltage
during the normal copy cycle.
The output voltage will display "0" when this mode is
accessed after turning on the main switch without
making any copies.
Adjusts the ADS reference voltage.
After adjusting the light intensity (SP48), place 5
sheets of A4(LT) white paper on the exposure glass
and select this mode. Adjust the ADS voltage to 2.5
V ± 0.1 V using VR101 on the main control board.
Displays the ADS output voltage.
Press the ! key to monitor the output voltage
during the normal copy cycle.
For only this SP mode, the copies are made with the
ADS mode (other SP modes use manual ID level 4).
4-18
CÓPIA NÃO CONTROLADA
Rev. 09/99
Settings
120 V Machines
180°C ~ 195°C
Default = 190°C
230 V Machines
180°C ~ 200°C
Default = 190°C
120 V Machines
160°C ~ 170°C
Default = 165°C
230 V Machines
165°C ~ 175°C
Default = 172°C
0 ~ 247
1 ~ 200
Default = 97
(0.02 V per
step)
0 ~ 255
Default = 102
(0.04 V per
step)
(0.02 V per
step) x Data
SM