Ricoh A219 Service Manual page 340

Table of Contents

Advertisement

Mode No.
Fusing
Displays the fusing temperature detected by the
Temperature
fusing thermistor.
52
Display †
Press the
during the normal copy cycle.
TD Sensor
If the setting of SP30 (Toner Supply Mode
Target Control
Selection) is 1 or 3, this value is used for the TD
53
Voltage
sensor target voltage.
Adjustment
Normally, this value should not be changed.
TD Sensor
When the TD Sensor initial setting is performed, this
54
Gain
mode is adjusted automatically.
Adjustment
Normally, this value should not be changed.
TD Sensor
Displays the TD sensor output voltage.
Output Display
Press the
Data †
during the normal copy cycle.
55
The output voltage will display "0" when this mode is
accessed after turning on the main switch without
making any copies.
ADS
Adjusts the ADS reference voltage.
Reference
After adjusting the light intensity (SP48), place 5
56
Voltage
sheets of A4(LT) white paper on the exposure glass
Adjustment
and select this mode. Adjust the ADS voltage to 2.5
V ± 0.1 V using VR101 on the main control board.
ADS Output
Displays the ADS output voltage.
Voltage
Press the
57
Display †
during the normal copy cycle.
For only this SP mode, the copies are made with the
ADS mode (other SP modes use manual ID level 4).
Image
Adjusts the image density at ID level 1 by changing
Adjustment at
the development bias voltage.
ID Level 1
SP Setting
58
Optics
Displays the optics temperature detected by the
Temperature
optics thermistor.
59
Display †
Press the
during the normal copy cycle.
Drum Potential
Factory use only.
60
Measurement
(With Paper)
Drum Potential
Factory use only.
61
Measurement
(Without Paper)
SM
CÓPIA NÃO CONTROLADA
Function
!
key to monitor the temperature
!
key to monitor the output voltage
!
key to monitor the output voltage
Setting
Dev. Bias
0
Normal
–200
1
Darker
–140
!
key to monitor the temperature
11-33
CÓPIA NÃO CONTROLADA
PROGRAM MODE
Settings
1 ~ 200
Default = 97
(0.02 V per step)
0 ~ 255
Default = 102
(0.04 V per step)
(0.02 V per
step) x Data
0: Normal
1: Darker
Note
Default
A245

Advertisement

Table of Contents
loading

This manual is also suitable for:

B019A245