Machine Check Logout Frame - 630/620
The TL6 Machine Check 630/620 logout frame provides error information to the
operating system error handler. When a fault is detected, PALcode enters a
error handler, captures the state of the processor and system, and builds a
logout frame. One frame is built for both processor and system detected errors
that are correctable. Machine check logout 630 contains EV6 CPU specific
errors registers while machine check logout 620 contains system specific error
registers.
63 ... 48
Common Area:
R|S|D|C|
System Area Offset
MCHK Frame Rev 8.
CPU Area:
63 ... 48
System Area:
DOF_CNT
47 ... 32
31 ... 16
Frame Size
CPU Area Offset
MCHK CODE
ISTAT
DC_STAT
C_ADDR
DCI_SYNDROME
DCO_SYNDROME
C_STAT
C_STS
MM_STAT
47 ... 32
31 ... 16
MISCR | WHAMI
TLBER
TLESR1
TLESR3
RESERVED
RESERVED
RESERVED
15 ... 00
00
08
10
18
20
28
30
38
40
48
50
15 ... 00
58
TLDEV
60
TLESR0
68
TLESR2
70
78
80
88
DECevent Error Log
4-41