3.4

Testing the Entire System

The test command with no modifiers runs all exercisers for subsystems
and devices on the system.
Example 3–4 Sample Test Command for the Entire System
P00>>>test
Console is in diagnostic mode
Complete Test Suite for runtime of 1200 seconds
Type ^C to stop testing
Configuring system...
:
:
Memory Tests not run.
Starting network exerciser on ewa0.0.0.12.0 (id #28f) in internal loopback mode
Starting network exerciser on ewb0.0.0.11.0 (id #2a1) in internal loopback mode
Starting network exerciser on ewc0.0.0.12.4 (id #2b3) in internal loopback mode
Starting network exerciser on ewd0.0.0.11.4 (id #2c5) in internal loopback mode
Starting device exerciser on dka0.0.0.4.0 (id #36f) in READ-ONLY mode
Stopping device exerciser on dka0.0.0.4.0 (id #36f)
Starting device exerciser on dka100.1.0.4.0 (id #5df) in READ-ONLY mode
Stopping device exerciser on dka100.1.0.4.0 (id #5df)
Starting device exerciser on dka200.2.0.4.0 (id #858) in READ-ONLY mode
Stopping device exerciser on dka200.2.0.4.0 (id #858)
Starting device exerciser on dka300.3.0.4.0 (id #acc) in READ-ONLY mode
Stopping device exerciser on dka300.3.0.4.0 (id #acc)
Starting device exerciser on dka400.4.0.4.0 (id #d37) in READ-ONLY mode
Stopping device exerciser on dka400.4.0.4.0 (id #d37)
Stopping all testing...
Stopping network exerciser on ewd0.0.0.11.4 (id #2c5)
Stopping network exerciser on ewc0.0.0.12.4 (id #2b3)
Stopping network exerciser on ewb0.0.0.11.0 (id #2a1)
Stopping network exerciser on ewa0.0.0.12.0 (id #28f)
---------Testing done ------------
3-8
Service Manual
Must run separately using TEST MS7CC*
please wait
˜