4.6.2

Machine Check Logout Frames

Machine Check Logout Frame - 670/660
The TL6 Machine Check 670/660 logout frame provides error information to the
operating system error handler. When a fault is detected, PALcode enters a
error handler, captures the state of the processor and system, and builds a
logout frame. One frame is built for both processor and system detected errors.
Machine check logout 670 contain EV6 CPU specific error registers while
machine check logout 660 contains system specific error registers.
63 ... 48
Common Area:
R|S|D|C|
System Area Offset
MCHK Frame Rev
CPU Area:
47 ... 32
31 ... 16
Frame Size
CPU Area Offset
MCHK CODE
ISTAT
DC_STAT
C_ADDR
DCI_SYNDROME
DCO_SYNDROME
C_STAT
C_STS
MM_STAT
EXC_ADDR
IER_CM
I_SUM
RESERVED
PAL_BASE
I_CTL
PCTX
RESERVED
RESERVED
DECevent Error Log
15 ... 00
00
08
10
18
20
28
30
38
40
48
50
58
60
68
70
78
80
88
90
98
4-39