IG 3000361032 - 01
• Last remote order... (T_DATE_SEUIL_NOIR) : date of the last remote readout triggered by the
toner criterion, or installation date if there has not been any previous remote readout;
• (XXXX pages) (T_CPT_NOIR ) : value of the cumulative number of pages printed at the date of
the previous remote readout triggered by the toner criterion (or 0 if there has not been any
previous remote readout).
• Last renewal... (T_DATE_CHG_NOIR) : date of the last Black toner cartridge renewal.
Scanner
• Estimated pages (T_INIT_OPC): Estimated number of pages before the next revision;
• Pages threshold (T_SEUIL_ OPC): trigger level (expressed as the number of pages remaining to
be printed) for the transmission of a remote readout triggered by the revision threshold criterion,
entered by the installer;
• Last remote order... (T_DATE_SEUIL_ OPC): date of the last remote readout triggered by the
revision criterion, or installation date if there has not been any previous remote readout;
• (XXXX pages) (T_CPT_OPC): value of the cumulative number of pages printed at the date of
the previous remote readout triggered by the revision criterion (or 0 if there has not been any
previous remote readout).
• Last renewal... (T_DATE_CHG_ OPC): date of the last revision.
Service operation
• Estimated pages (T_INIT_FOUR): Estimated number of pages before the next revision;
• Pages threshold (T_SEUIL_ FOUR): trigger level (expressed as the number of pages remaining
to be printed) for the transmission of a remote readout triggered by the revision threshold
criterion, entered by the installer;
• Last remote order... (T_DATE_SEUIL_ FOUR): date of the last remote readout triggered by the
revision criterion, or installation date if there has not been any previous remote readout;
• (XXXX pages) (T_CPT_FOUR): value of the cumulative number of pages printed at the date of
the previous remote readout triggered by the revision criterion (or 0 if there has not been any
previous remote readout).
• Last renewal... (T_DATE_CHG_ FOUR): date of the last revision.
Emission informations
• Reason of emission (TCAUSE_EMIS): reason for the remote readout transmission;
• Hour of emission (TDATE_EMIS): date of the remote readout transmission;
6.4
R
EMINDERS
• Every MFP is equipped with a copy counter, implemented in EEPROM memory on the CPU
board. This counter is used in particular by the Remote Readout function. It can be consulted by
the user (see § of the Installation Guide). This counter cannot be modified. It is stored
indefenitely.
• Before any corrective intervention on the machine that risks modifying the installation
parameters or the value of the counter (replacement of the CPU board or installation of new
software), a manual Remote Readout transmission should be performed, if the state of the
machine allows it. If this transmission is not possible for any reason, print out the Remote
Readout parameters or display the copy counter and note these values on the intervention report.
- 44 -