Frequency Conversion Monitor (D012) - Hyundai n 700 Instruction Manual

Hide thumbs Also See for n 700:
Table of Contents

Advertisement

N700 Operating Instructions and Parts Manual
5.12

Frequency conversion monitor (d012)

(1) This inverter displays the value changed by the inverter output frequency and the value set in
b009 on the monitor part.
"Display of monitor part " = "Output frequency(d001)" x "Output frequency factor(b009)"
(2) 0.00 ~ 99.99 : Display is in 0.01 unit.
100.0~400.0 : Display is in 0.1 unit.
Note) Output frequency of FM terminal becomes same as d012 at the time of setting up the
5.13
Accumulated time monitor during RUN (d013)
(1) The operation time of inverter is accumulated and the value is displayed.
(2) 0 ~ 9999 : Display is in 1 hour units.
When the value is more than 10,000 hours, the last point added in the LED display. (1000. ~
6553.) The maximum value is '6553.'.
5.14
Accumulated time monitor during RUN (d014)
(1) The operation time of inverter is accumulated and the value is displayed.
(2) 0 ~ 59 : Display is in 1 min. Units.
5.15
Power ON time monitor (d015)
(1) This accumulates the time running to the inverter and displays the value.
(2) 0 ~ 9999 : Display is in 1 hour units. When the value is more than 10,000 hours, the last point
added in the LED display. (1000. ~ 6553.) The maximum value is '6553.'.
5.16
Power ON time monitor (d016)
(1) This accumulates the time running to the inverter and displays the value.
(2) 0 ~ 59 : Display is in 1 min. units.
5.17
IGBT Power Module Temperature monitor (d017)
(1) This monitor function displays the sensing temperature of IGBT Power Module.
(2) 0 ~ 9999 : Display is in 1
(3) When the heatsink overheat trip is occurred, inverter displays trip temperature until reset.
5.18
Trip count(d018)
(1) This displays the number of inverter trips.
(2) 0 ~ 9999 : Display is in 1 units.
5.19
Trip monitor 1 to 6(d019~d024)
(1) This displays the details for the last six protective trips.
(2) The trip monitor 1 displayed the details of the last trip.
① Trip code
② Output frequency on tripping (Hz)
digital output frequency to the FM terminal. (FM output setting (o009) = 3)