Selection Of Motor Control Method - Hyundai n 700 Instruction Manual

Hide thumbs Also See for n 700:
Table of Contents

Advertisement

N700 Operating Instructions and Parts Manual
12.1.2

Selection of motor control method

(1) It is possible to select the motor control method in F012 (motor control method) for the
precise motor control.
(2) The N700 inverter is possible to do speed control and torque control using the speed-control
mode and torque-control mode. It is possible to select each function in the parameter F018.
Code
Function Name
Motor control
F012
method
Second motor
F212
Control method
Motor voltage
F013
selection
F015 Motor capacity
Second motor
F215
capacity
Motor pole
F016
selection
Second motor
F216
pole selection
Motor rated
F017
current
Second motor
F217
rated current
SLV Control
F019
method selection
Note1) In 1st motor control method (F012), it is possible to select setting range 0~3 , 5~7.
In 2nd motor control method (F212), it is possible to select setting range 0~3, 5.
Note2) The motor rated current for F017/F217 code is the factory setting value according to the
inverter capacity.
You can adjust this parameter according to applicable motor.
Note3) The data of F012 must be setted range 5~7.
The data of F212 must be setted range 5.
Initial
Setting
Unit
value
range
0~3,
5
-
5~7
5
-
0~3,5
220
200~240
V
(440)
(380~480)
Factory
1.5~75
setting
Factory
1.5~75
setting
4
pole
2~12
4
pole
2~12
Factory
A
0.0~999.9 Rated current value[RMS]
setting
Factory
A
0.0~999.9 Rated current value[RMS]
setting
0
-
0~1
Table 12- 2 Selection of motor control method
134
12. Explanation of H-Group
Contents
0(VC) : Constant torque characteristic
1(VP1) : Reduced torque characteristic(1.7)
2(VP2) : Reduced torque characteristic(1.7)
3(Free V/f) : V/f free setting
5(SLV) : Sensorless vector control
6(V2) : Sensored vector control
7(0Hz-V2) : 0Hz-domain sensored vector control
0(VC) : Constant torque characteristic
1(VP1) : Reduced torque characteristic(1.7)
2(VP2) : Reduced torque characteristic(1.7)
3(Free V/f ) : V/f free setting
5(SLV) : sensorless vector control
200/215/220/230/240 – 200V class setting
380/400/415/440/460/480 – 400V class setting
1.5/2.2/3.7/5.5/7.5/11/15/18.5/22/30/37/45/55/75
1.5/2.2/3.7/5.5/7.5/11/15/18.5/22/30/37/45/55/75
2/4/6/8/10/12
2/4/6/8/10/12
0 : Normal Operation
1 : 0Hz Operation