Fundamental Functions(F-Group) - Hyundai n 700 Instruction Manual

Hide thumbs Also See for n 700:
Table of Contents

Advertisement

N700 Operating Instructions and Parts Manual
4.2.3

Fundamental functions(F-group)

Code
Function name
F001
Output frequency setting
Output frequency setting,
F201
2nd motor
F002
Base frequency setting
F202
Base frequency, 2nd motor
F003
Maximum frequency setting
Maximum frequency setting,
F203
2nd motor
F004
Starting frequency setting
F005
Frequency upper limit
Frequency upper limit, 2nd
F205
motor
F006
Frequency lower limit
Frequency lower limit, 2nd
F206
motor
F007
Accelerating time setting
Accelerating time setting,
F207
2nd motor
F008
Decelerating time setting
Decelerating time setting,
F208
2nd motor
F009
Driving direction selection
F010
Frequency source selection
RUN command source
F011
selection
F012
Motor control method
F212
Second motor control method
Motor voltage selection
F013
(Motor rated voltage)
F014
Output voltage gain
Motor capacity selection
F015
(Motor rated capacity)
2nd Motor capacity selection
F215
(Second motor rated capacity)
F016
Motor pole selection
F216
Second motor pole selection
F017
Motor rated current setting
F217
Second motor rated current
F018
Speed/Torque mode selection
F019
SLV control method selection
0.00~99.99/100.0~400.0[Hz]
0.00~99.99/100.0~400.0[Hz]
30.00~99.99/100.0~400.0, up to max. frequency[Hz]
30.00~99.99/100.0~400.0, up to max. frequency[Hz]
30.00~99.99/100.0~400.0, from base frequency[Hz]
30.00~99.99/100.0~400.0, from base frequency[Hz]
0.10~10.0[Hz]
0.00~99.99/100.0~400.0[Hz]
Frequency min. ~ Max. frequency
0.00~99.99/100.0~400.0[Hz]
Frequency min. ~ Max. frequency
0.00~99.99/100.0~400.0[Hz]
Starting frequency ~ Max. frequency
0.00~99.99/100.0~400.0[Hz]
Starting frequency ~ Max. frequency
0.1~999.9,1000.~3600.[sec]
0.1~999.9,1000.~3600.[sec]
0.1~999.9,1000.~3600.[sec]
0.1~999.9,1000.~3600.[sec]
0(FWD), 1(REV)
0(OPE VOL), 1(TERMINAL), 2(OPE KEYPAD),
3(COM), 4(OPT1), 5(OPT2)
1(TERMINAL), 2(OPE), 3(COM), 4(OPT1), 5(OPT2)
0(VC), 1(VP1), 2(VP2), 3(FREE V/f), 4(SLV-I),
5(SLV-D), 6(V2), 7(0Hz-V2)
0(VC), 1(VP1), 2(VP2), 3(FREE V/f), 4(SLV-I), 5(SLV-D)
200/215/220/230/240[V]
380/400/415/440/460/480[V]
20~100[%]
1.5/2.2/3.7/5.5/7.5/11/15/18.5/22/30/37/45/55/75
/90/110/132/160[㎾]
1.5/2.2/3.7/5.5/7.5/11/15/18.5/22/30/37/45/55/75
/90/110/132/160[㎾]
2/4/6/8/10/12[Pole]
2/4/6/8/10/12[Pole]
0.0~999.9[A]
0.0~999.9[A]
0(Speed control mode)/1(Torque control mode)
0(Normal operation mode), 1(0Hz operation mode)
Table 4- 3 Fundamental functions(F-group)
29
Setting range
4. Parameter Code List
Change
Initial
Page
mode
Data
on run
0.00
46
0.00
46
60.00
46
60.00
46
60.00
47
60.00
47
0.50
48
0.00
48
0.00
48
0.00
48
0.00
48
30.0
49
30.0
49
30.0
49
30.0
49
0
50
0
50
2
51
0
52
0
52
220
53
(440)
100
54
Factory
54
setting
Factory
54
setting
4
54
4
54
Factory
55
setting
Factory
55
setting
0
55
0
55

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hi run n 700