Terminal Connection Diagram - Hyundai n 700 Instruction Manual

Hide thumbs Also See for n 700:
Table of Contents

Advertisement

N700 Operating Instructions and Parts Manual
2.2.3

Terminal connection diagram

(1) Terminal connection diagram
① The control circuit terminal of inverters is connected with the control board in unit.
(2) Wiring
① Both the CM1 and L terminals are insulated to both the common terminal of the input and
output signals.
Do not short or connect to ground these common terminals.
② Use twisted screened cable, for the input and output wires of the control circuit terminals.
Connect the screened cable to the common terminal.
③ Limit the connection wires to 65 feet.
④ Separate the control circuit wiring from the main power and relay control wiring.
⑤ When using relays for the FW terminal or an intelligent input terminal use a control relay
that is designed to work with 24Vdc.
Terminal for CAN Communication
Terminal for RS232/RS485 Communication
Fig. 2- 7 Terminal connection diagram