Maintenance
Disassemble the bearing frame
1.
Remove these plugs from the bearing frame (228A).
2.
For the MTi and LTi models, remove the bearing frame foot-to-frame bolts (370F) and the frame foot
(241).
408W
761B
408N
408M
Guidelines for i-ALERT
Precautions
WARNING:
• Never heat the condition monitor to temperatures in excess of 300°F (149°C). Heating to these
temperatures could result in death or serious injury.
• Never dispose of the condition monitor in a fire. This could result in death or serious injury.
Guidelines
The battery contained in the condition monitor does not contain enough lithium to qualify as reactive
hazardous waste. Use these guidelines when disposing of the condition monitor.
• The condition monitor is safe for disposal in the normal municipal waste stream.
• Adhere to local laws when you dispose of the condition monitor.
82
122
382
136
112A
• oil-fill plug (113A)
• oil-drain plug (408A)
• sight-oiler plug (408J)
• four oil mist/grease connection plugs (408H)
• oil-cooler inlet and outlet plugs (408L and 408M) or oil cooler
113A
372T
370F
™
Condition Monitor disposal
Model HT 3196 i-FRAME Installation, Operation, and Maintenance Manual
408W
319
408N
408A
241
Need help?