Mounting RADWIN Lighting Protection unit

Figure 17-5: ODU Lightning Protector and grounding
Mounting RADWIN Lighting Protection unit
To mount a lightning protection device:
1. Mount the device as close to the ODU as possible.
2. Mount the unit to on the pole using the supplied band.
3. Connect the ODU-IDU cable using the RJ-45 jack.
4. Connect one cable between the ODU and the protector using an RJ-45 jack.
5. Connect the protector's ground stud to a grounding point. Use the appropriate wire
gauge and type, keeping the wire as short as possible, less than 1m (3'), between
the stud and the site grounding point.
There may also be regulatory requirements to cross bond the ODU-IDU CAT-
5e cable at regular intervals up the mast. This may be as frequent as every
10 meters (33 feet).
Note
A second lightning protector Unit should be mounted at the building entry point and must be
grounded, as shown in
RADWIN 5000 HPMP User Manual
Figure 17-4
above.