Active Alarms; Other Diagnostic Aids; Link Budget Calculator - Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

Active Alarms

Table 8-4: RADWIN Manager Trap Messages (Continued)
Trap Message
The Manager identified a newer ODU release at the
<remote_site_name> site.
The Manager identified a newer ODU release at the
<local_site_name> site.
Newer Version identified at the <local_site_name> site.
Newer Version identified at the <remote_site_name> site.
Newer Version Identified!
Active Alarms
Active Alarms are raised for any event affecting availability or quality of service.
The Active Alarms button,
Current Active Alarms may be saved to a file. The list displayed will not be updated unless you
click Refresh.

Other Diagnostic Aids

Link Budget Calculator

The Link Budget Calculator is part of the RADWIN Manager software and is found in the Help
menu. This useful utility enables you to calculate the expected performance of the wireless
link and the possible configurations for a specific link range including antenna size, cable loss
and climate conditions. For full details, see
RADWIN 5000 HPMP User Manual
Severity
Warning
Warning
Warning
Warning
Warning
is available for the HBS and the HSUs.Her is an example:
Chapter
18.
Release 3.2.00
Chapter 8
Remarks
ODU release is newer than RADWIN Manager
release.
Wizards are not available. RADWIN Manager will
be used just for monitoring. Upgrade the RADWIN
Manager. (You will get this message as a pop up)
ODU release is newer than RADWIN Manager
release.
Wizards are not available. RADWIN Manager will
be used just for monitoring. Upgrade the RADWIN
Manager.
8-14