Mib Traps - Radwin 5000 HPMP User Manual

Point to multipoint broadband wireless
Hide thumbs Also See for 5000 HPMP:
Table of Contents

Advertisement

MIB Traps

Table C-2: Private MIB Parameters (Sheet 25 of 25)
Name
winlink1000HsuAirRemoteCompressedStatic
winlink1000HsuServiceCommandStr
winlink1000GeneralTrapDescription
winlink1000GeneralTrapSeverity
winlink1000GeneralCookie
winlink1000GeneralEcChangesCounter
winlink1000GeneralTelnetSupport
winlink1000GeneralWISupport
MIB Traps
General
Each ODU can be configured with up to 10 different trap destinations. When the link is oper-
ational, each ODU sends traps originating from both Site A and Site B.
The source IP address of the trap is the sending ODU. The trap originator can be identified by
the trap Community string or by the trap description text.
Each trap contains a trap description and additional relevant information such as alarm sever-
ity, interface index, time stamp and additional parameters.
RADWIN 5000 HPMP User Manual
OID
1.3.6.1.4.1.4458.1000.100.1
1.3.6.1.4.1.4458.1000.100.2
1.3.6.1.4.1.4458.1000.100.3
1.3.6.1.4.1.4458.1000.100.4
1.3.6.1.4.1.4458.1000.100.5
1.3.6.1.4.1.4458.1000.100.6
Release 3.2.00
Type
Description
RO
Holds all the configuration data of the HBS in a
compressed format. Helps the NMS to get info
regarding new Unregistered links. Fields
Included: Location (32 bytes) IP address (8
bytes in hexa) Subnet mask (8 bytes in hexa)
HBS Antenna type (1 byte) HBS Agent Version
(4 bytes)
RW Ability to perform special command in the HSU.
Format (string): Operation Param1 Param2 ....|
ParamN.
DisplayString
RO
Trap's Description. Used for Trap parameters.
Integer
RO
Trap's Severity. Used for Trap parameters.
DisplayString
RW Reserved for the Manager application provided
with the product used for saving user preferences
affecting ODU operation.
Integer
RO
This counter is initialized to 0 after a device reset
and is incremented upon each element constant
write operation via SNMP or Telnet.
Integer
RW Enable/Disable Telnet protocol.
Integer
RW Enable/Disable Web Interface protocol.
Mandatory Disabled - No option to enable the
feature.
disable the feature.