RADWIN Manager Traps

BBER Threshold

The Background Block Error Ratio is measured as a percentage. The threshold can be set
from 0.1% up to 50%.
An 8% threshold is recommended. If there are no problems during the interval, then for that
threshold, the recommended BBER value should be 0. Since the system provides a lossless
Ethernet service, there is throughput degradation in case of interference. The degradation is
proportional to the BBER.

Ethernet Thresholds - Capacity

This is used as a basis for checking adherence to a Service Level Agreement. It is the number
of seconds count that the link capacity falls bellow the threshold.
Ethernet Thresholds - Traffic
The number of seconds count that received traffic exceeded this threshold. It can be used to
measure traffic peaks.
RADWIN Manager Traps
The RADWIN Manager application issues traps to indicate various events, displayed in the
Events Log.
Table 8-4: RADWIN Manager Trap Messages
Trap Message
Cannot bind to trap service port. Port 162 already in use by
ProcessName (pid: ProcessId)
Device unreachable!
Connected to <site_name>
<site_name> Site will be reset.
Restore Factory Default Settings in process on Site <site_name>
Factory Settings: The process was not finished due to connection
issues.
Reset: The process was not finished due to connection issues.
Cannot Write to Monitor file. There is not enough space on the disk.
Windows Error: <error_ID>. Cannot Write to Monitor file.
Identical IP addresses at <local_site_name> and
<remote_site_name>
The Product is not identified at the <local_site_name> site.
The Product is not identified at the <remote_site_name> site.
The Product is not identified at both sites.
Product Not Identified!
RADWIN 5000 HPMP User Manual
Severity
Warning
Error
Information
Information
Information
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Warning
Release 3.2.00
Chapter 8
Remarks
RADWIN Manager will not catch any traps from the
ODU, some other application has grabbed this
port.
Check connectivity to ODU
Factory setting failed due to connectivity problem
to ODU
Factory setting failed due to connectivity problem
to target - ODU will not be reset
Free some space on disk on the managing
computer and retry
Operating System error on the managing computer
Set up a different IP to each site
RADWIN Manager is incompatible with the ODU
software version