Technical Specifications

Scope of these Specifications
This appendix contains technical specifications for the major link components appearing in
this User Manual. They are correct at the date of publication, but are intended for general
background only. The latest authoritative and most up to date technical specifications are
available as Data Sheets obtainable from RADWIN Customer Service.
In any event, RADWIN reserves the right to change these specifications without notice.
ODU - HBS and HSU
Capacity
Range
Radio Modulation
Adaptive Modulation & Coding
Automatic Channel Selection
DFS
Diversity
Spectrum View
Duplex Technology
Error Correction
Rate – Dual Antenna [Mbps] at 20
MHz CBW
Rate – Single Antenna [Mbps] at 10
MHz CBW
Modulation
FEC [k=]
Max Tx Power [dBm] for 4.8 – 6 GHz
Sensitivity (dBm) @BER <10e-11 at
20 MHz CBW
For 10 MHz CBW, deduct 3 dBm
Encryption
RADWIN 5000 HPMP User Manual
HBS: Up to 200Mbps aggregate net throughput depending on regulation
HSU: Up to 50 Mbps aggregate net throughput depending on model
Up to 40 km / 25 miles
2x2 MIMO-OFDM (BPSK/QPSK/16QAM/64QAM)
Supported
Supported
Supported
Supported
Supported
TDD
FEC k = 1/2, 2/3, 3/4, 5/6
13
26
39
6.5
13
19.5
BPSK
QPSK
1/2
1/2
3/4
25
-88
-86
-83
AES 128
Release 3.2.00
Appendix A
52
78
104
26
39
52
16QAM
1/2
3/4
2/3
24
21
19
-81
-77
-72
117
130
58.5
65
64QAM
3/4
5/6
18
-70
-67
A-1