Understanding The Lights; Armed Light; Bypass Light; Cancel Light - GE NETWORX NX-108E User Manual

Networx nx-4
Hide thumbs Also See for NETWORX NX-108E:
Table of Contents

Advertisement

UNDERSTANDING THE LIGHTS

Armed Light

The armed light is "on" when the system is armed. The armed light is "off"
when it is disarmed. The armed light will flash when there has been an alarm
during the previous arm cycle.

Bypass Light

The bypass light is "on" when any zone is bypassed. The zone(s) that is
bypassed will also be illuminated. If the bypass light is "off", no zones are
bypassed.

Cancel Light

The cancel light will flash during an abort delay time. If a code is entered
followed by the [CANCEL] key while this light is flashing, all abortable reports
will stop the communication process. Note: The abort feature must be
enabled. Entering a code followed by the [CANCEL] key during or after an
alarm report to the central station will cause the cancel light to come on. It will
stay on until the central station has received the cancel report. Note: The
cancel feature must be enabled. No additional keypad tones will be emitted.

Chime Light

The chime light is "on" when the chime feature is "on"; "off" otherwise.

Exit Light

The exit light is "on" during the exit delay. During the last 10 seconds of the exit
delay, the exit light will flash rapidly and the keypads will beep rapidly as a
warning to the user that the exit time is about to expire. (The user may want to
disarm the system if the exit light is flashing in order to prevent an alarm. The
user may then re-arm the system and exit before the delay expires.)

Fire Light

A steady fire light means a fire zone has been faulted. A rapidly flashing fire
light means that a fire zone is in a trouble condition.

Instant Light

The instant light is "on" when there is no delay on your entry/exit door(s). Any
time the instant light is "on" and the exit delay has expired, the opening
of an entry/exit door will produce an immediate alarm. The instant light can
be toggled on or off by pressing the [Stay] key while the system is armed.
When the instant light is "off", the entry/exit door(s) is delayed.

Power Light

The power light is on if the primary power is on. The power light will flash if the
system has a low battery condition.

Ready Light

The ready light is "on" when the system is ready to arm and "flashes" if ready to
force arm. The ready light is off when the system is not ready to arm because
of a zone(s) being faulted.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents