Option 38: Alarm Cancel Timeout

The Alarm Cancel Timeout option determines the number of minutes your
customer has to cancel an alarm. Alarm reports are sent immediately to the
central station; if an alarm is cancelled within the specified time, an Alarm
Cancel Report is also generated.
If an alarm is cancelled after a report has been sent, a subsequent cancel
report is also generated.
Note
If the Alarm Cancel Timeout option is set to OFF, an alarm cannot be cancelled
and the panel will not announce "or press STATUS to cancel."

Option 39: Audio Session Cancel

When Audio Session Cancel is set to ON, all audio sessions are disabled
after an alarm has been cancelled. When the option is set to OFF, audio ses-
sions continue to occur after an alarm has been cancelled.
Note
For Audio Session Cancel to function properly, you must enable Alarm Cancel
Timeout (Option 38) and set AVM Enable (Option 24) to ON.

Option 40: Report Medication Failure at Supervisory Time

When Option 40 is set to 1, a Failure to Take Medication Report is sent at
the Supervisory Time. When the option is set to 0, a Failure to Take Medica-
tion Report is sent immediately.
When the option is set to OFF, all medication reminders are disabled.
All pager and voice event notifications, regardless of Option 40 settings, are
sent immediately.

Option 41: Activity Check

The Activity Check option allows you to establish a time period during
which the panel monitors for activity but does not generate a No Activity
Report.
If the panel does not detect activity after the set time period expires, a No
Activity Report is generated and sent to the central monitoring station.
All entries must contain two digits.

Option 42: Siren Time Out

In cases of an activated alarm, the Siren Time Out option controls how long
the siren will sound. If the option is disabled, you must press Status to can-
cel an activated siren.
All entries must include three digits.

Option 43: Set House Code

The Set House Code option establishes a house code for each X10 device.
In cases of activity alarm or medication reminder, the panel flashes X10-
controlled lights.
The house code programmed into the panel must match the house code pro-
grammed into the selected X10 device. Refer to X10 Module Instructions for
further details.
Note
In order to use an X10 module with the CareGard panel, you must replace the fac-
tory-installed transformer with a specialized X10 transformer (60-972).
Use of the X10 module with this panel has not been investigated by ETL.
Programming Options
Range = 3-254 Min, Off (Default = 005)
¾
To program Alarm Cancel Timeout:
1. Press Add.
2. Press Option #.
3. Press 3, then 8.
4. Enter the number of minutes for the Alarm
Cancel Timeout setting.
5. Press Done.
Range = On/Off (Default = Off)
¾
To program Audio Session Cancel:
1. Press Add or Delete.
2. Press Option #.
3. Press 3, then 9.
4. Press Done.
Range = 0, 1, Off (Default = Off)
¾
To program Report Med. Failure:
1. Press Add or Delete.
2. Press Option #.
3. Press 4, then 0.
4. Press Done.
Range = 2-48 Hours, Off (Default = Off)
¾
To program Activity Check:
1. Press Add.
2. Press Option #.
3. Press 4, then 1.
4. Enter the number of Activity Check hours.
5. Press Done.
Range = 2-254 Min, Off (Default = 004)
¾
To program Siren Time Out:
1. Press Add.
2. Press Option #.
3. Press 4, then 2.
4. Enter the Siren Time Out minutes.
5. Press Done.
Range = A - O (Default = A)
¾
To program Set House Code:
1. Press Add.
2. Press Option #.
3. Press 4, then 3.
4. Press 9 to enter the desired House Code.
Each time you press 9, the house code
advances one letter.
5. Press Done.