Silent Exit; Exit Extension; No Delay-For Instant Alarm; Auto Stay Arm - GE Allegro 60-874-95R User Manual

Allegro ge
Hide thumbs Also See for Allegro 60-874-95R:
Table of Contents

Advertisement

Note
The Exit Extension will work
on the first re-entry only.
Note
If Quick Arm feature is on,
an access code is not
required.
Note
Your installer/dealer can turn
this option on or off for you.
See Table B4: System
Options, on page 19 to see if
this feature is available to
you.

Silent Exit

Use the Silent Exit feature to arm your system without disturbing people throughout the house
with arming status beeps. By pressing the silent exit button prior to arming or during the exit
delay will mute the time progress tones at the panel. If silent exit is selected, the exit delay is dou-
bled.
To use silent exit:
Press the Silent button, the

Exit Extension

Your system may be set up so that the delay time is restarted if you re-open the delay door during
the initial delay time.
This is useful if, after arming the system, you walk out the door, then remember something you
forgot inside. You can re-enter and exit through the delay door without disarming and re-arming
the system.
If your system is not using this feature, you must disarm the system when you re-enter the armed
premises to avoid setting off an alarm. The dealer/installer can turn this feature on or off for you.
See Table B4: System Options, on page 19, to see if this feature is available to you.
No Delay—For Instant Alarm
You can choose to turn off the Entry and Exit Delays, causing the delay doors to arm immedi-
ately by pressing the No Delay button within 5 seconds of arming the system. Anyone entering or
exiting the house through the delay door when the system is set to No Delay would immediately
cause an alarm.
No Delay is normally used:
When you're staying at home, after you've armed the system.
When you're arming your house from the outside. (You must have an installer programmed
keychain touchpad with Keychain Touchpad Arm set to on in order to do this).
Arming to Level 2 (or 3) with no delay, using the panel keypad:
1. Close all perimeter doors and windows.
2. Press
once (or twice).
3. Enter your access code. The system sounds two (or three) beeps.
4. Immediately after hearing the beeps, press
and
Doors and Windows - No Delay (
Arming to Level 2 (or 3) with no delay, using the wireless touchpad:
1. Press the desired arm button.
2. Enter your access code.
3. Press
to eliminate the delay time.
Changing the arming level will restore delay doors to their normal Exit and Entry Delay times.
Arming directly to Level 3 with no delay using the keychain touchpad:
Press the
once.

Auto STAY Arm

The Auto STAY Arming feature helps cut down on false alarms in the event that you arm the sys-
tem to Level 3, but fail to leave during the Exit Delay time. Here's how it works:
If you arm the system to Level 3, and do not leave the premises within the Exit Delay time:
The system can tell that no one opened and closed a delay door within the delay
If feature
time. It assumes that someone is still inside and the panel will arm to Level 2 to avoid
turned on.
a false alarm. Your movement inside the premises will not cause an alarm.
button and then enter your code. The system will arm silently.
for
No Delay
or
Motion Sensors, Doors and Windows - No Delay)
. The panel displays the current time
.
9