4.1.10. Anti-crushing Sensitivity

The D5-Evo DOMESTIC, D10 and the
D10 Turbo incorporate a sensitive
electronic anticrushing technology
that activates if a person or vehicle
obstructs your gate.
The operator will respond differently
to obstructions depending on the
Operating Standard (e.g. CE, UL325)
you select. The typical response for
an opening gate is to immediately
stop and a closing gate will stop then
immediately reopen.
Collision force can be set
independently per direction of travel
and can be set from minimum to
maximum in five incremental steps.
A sixth incremental step will disable
collision sensing entirely and allow
for maximum force – the motor will
run until it stalls at which point a
collision will be detected.
Step six should only
be used if additional
safety measures such
as Infrared beams and
sensitive edges are
present.

4.1.10.1. Collision Count

A counter monitors the number
of collisions the gate experiences
before it fully closes. If the number
exceeds the default value of four,
which can be adjusted in the Multiple
Collisions Counter, the controller will
shut down. The Status LED will flash
four times every second until a valid
trigger is received.
Please refer to Gate Status
Indication for more information on
this diagnostic device.
Gate closes, hits obstruction, stops and closes
immediately
Gate opens,
hits obstruction and stops