Mouse Diagnostic; Diskette Drive (Floppy) Diagnostic - Sun Microsystems Sun Blade 100 Service Manual

Sun blade 100 workstation service manual
Hide thumbs Also See for Sun Blade 100:
Table of Contents

Advertisement

4.7.2.5

Mouse Diagnostic

To start the mouse diagnostic, type
diagnostic performs a keyboard-to-mouse loopback test.
The following code example shows the mouse diagnostic output message.
CODE EXAMPLE 4-12
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===> 4
TEST='mouse_test'
SUBTEST='mouse_loopback'
###OBDIAG_MFG_START###
TEST='mouse_test'
STATUS='FAILED'
SUBTEST='mouse_loopback'
ERRORS='1 '
TTF='1656 '
SPEED='295.99 MHz'
PASSES='1 '
MESSAGE='Error: Timeout receiving a character'
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===>
4.7.2.6

Diskette Drive (Floppy) Diagnostic

To start the diskette drive (floppy) diagnostic, type
The diskette drive diagnostic verifies the diskette drive controller initialization. It
also validates the status of a selected disk drive and reads the diskette drive header.
The following code example shows the diskette drive test output message.
CODE EXAMPLE 4-13
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===> 5
TEST='floppy_test'
SUBTEST='floppy_id0_read_test'
Enter (0-12 tests, 13 -Quit, 14 -Menu) ===>
4-18
Sun Blade 100 Service Manual • October 2000
at the OBdiag Menu prompt. The mouse
4
Diagnostic
Mouse
Output Message
Diskette Drive
Diagnostic Output Message
at the OBdiag Menu prompt.