KYMCO PEOPLE 250 Service Manual page 30

Ymco people 250
Hide thumbs Also See for PEOPLE 250:
Table of Contents

Advertisement

1
. GENERAL INFORMATION
POOR CHARGING (BATTERY OVER DISCHARGING OR OVERCHARGING)
Undercharging
Inspection/Adjustment
Start engine and test
limit voltage of
battery terminals
Measure resistance
between AC generator
coil terminals
Test output voltage of
regulator/rectifier
coupler red wire
Overcharging
Inspection/Adjustment
Measure battery limit
voltage with an
electric tester
Check resistance
between regulator/
rectifier terminals
1-27
Symptom
Voltage does not
Normal voltage
increase
Normal
Normal voltage
Symptom
Normal
Normal
Resistance too
low
No voltage
Abnormal
Abnormal
PEOPL E 250
Probable Cause
ÅFaulty AC generator
ÇFaulty regulator/rectifier
ÉFaulty battery
ÅShorted AC generator coil
ÇOpen circuit between AC
generator 3 yellow wires
ÅFaulty regulator/rectifier
ÇFaulty AC generator
ÉLoose regulator/rectifier
coupler
ÑLimit voltage too high
Probable Cause
ÅFaulty battery
ÇFaulty regulator/rectifier
ÉBroken or poorly
connected
regulator/rectifier black wire
ÅLimit voltage too high

Hide quick links: