8
. DRIVE AND DRIVEN PULLEYS/
V-BELT
MOVABLE DRIVE FACE
ASSEMBLY
Remove the pulley face, clutch outer, driven
pulley and belt. ( 8-4))
Remove the movable drive face assembly.
Remove the drive pulley collar.
DISASSEMBLY
Remove the ramp plate.
Remove the weight rollers.
INSPECTION
Check each weight roller for wear or damage.
Measure each weight roller O.D.
Service Limit: 22.00mm replace if below
8-5
Movable Drive Face Assembly
Ramp Plate
PEOPL E 250
Drive Pulley Collar
Weight Roller