Battery/Charging System - KYMCO PEOPLE 250 Service Manual

Ymco people 250
Hide thumbs Also See for PEOPLE 250:
Table of Contents

Advertisement

16

. BATTERY/CHARGING SYSTEM

SERVICE INFORMATION
GENERAL INSTRUCTIONS
The battery electrolyte (sulfuric acid) is poisonous and may seriously damage the skin and
eyes. Avoid contact with skin, eyes, or clothing. In case of contact, flush with water and get
prompt medical attention
• The battery can be charged and discharged repeatedly. If a discharged battery is not used for a
long time, its service life will be shortened. Generally, the capacity of a battery will decrease after
it is used for 2
recharged but its voltage decreases suddenly and then increases when a load is added.
• When a battery is overcharged, some symptoms can be found. If there is a short circuit inside the
battery, no voltage is produced on the battery terminals. If the rectifier won't operate, the
voltage will become too high and shorten the battery service life.
• If a battery is not used for a long time, it will discharge by itself and should be recharged every 3
months.
• A new battery filled with electrolyte will generate voltage within a certain time and it should be
recharged when the capacity is insufficient. Recharging a new battery will prolong its service life.
• Inspect the charging system according to the sequence specified in the Troubleshooting.
• Do not disconnect and soon reconnect the power of any electrical equipment because the electronic
parts in the regulator/rectifier will be damaged. Turn off the ignition switch before operation.
• It is not necessary to check the MF battery electrolyte or fill with distilled water.
• Check the load of the whole charging system.
• Do not quick charge the battery. Quick charging should only be done in an emergency.
• Remove the battery from the motorcycle for charging.
• When replacing the battery, do not use a traditional battery.
• When charging, check the voltage with an electric tester.
SPECIFICATIONS
Battery
A.C. Generator
Regulator/Rectifier
TESTING INSTRUMENTS
Ammeter
Electric tester: YF-3501
Tachometer
3 years. A capacity-decreased battery will resume its voltage after it is
Item
Capacity
Voltage
Fully charged
(20
)
Undercharged
Charging current
Charging time
Capacity
Charging coil resistance (20
Charging rpm
Charging performance
Limit voltage
STD: 1.2 A Quick: 5.0A
STD: 5-10hr Quick:60min
180W/5000rpm
)
Yellow
1300rpm max (14V)
9A min/5000rpm
TORQUE VALUES
Pulser coil bolt
Coil lock bolt
Flywheel nut
PEOPL E 250
Standard
12V10AH
13.2V
12.3V
Yellow
1.6
2.5W
14.5±0.5V
4.9N-m
8.8N-m
58.8N-m
16-2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents