KYMCO PEOPLE 250 Service Manual page 136

Ymco people 250
Hide thumbs Also See for PEOPLE 250:
Table of Contents

Advertisement

12
. COOLING SYSTEM
SPECIFICATIONS
Radiator cap relief pressure
Thermostat temperature
Coolant capacity
COOLANT GRAVITY
Temp.
Coolant
concentration
5%
10%
15%
20%
25%
30%
35%
40%
45%
50%
55%
60%
COOLANT MIXTURE (WITH ANTI-RUST AND ANTI-FREEZING EFFECTS)
Freezing Point
-9
-15
-25
-37
-44.5
Cautions for Using Coolant:
• Use coolant of specified mixing rate. (The
mixing rate of 425cc KYMCO SIGMA
coolant concentrate + 975cc distilled
water is 30%.)
• Do not mix coolant concentrate of
different brands.
• Do not drink the coolant which is
poisonous.
• The freezing point of coolant mixture shall
be 5
lower than the freezing point of
the riding area.
12-3
Begins to open
Full-open
Valve lift
0
5
10
1.009 1.009 1.008 1.008 1.007 1.006 1.005 1.003 1.001 0.009 0.997
1.018 1.107 1.017 1.016 1.015 1.014 0.013 1.011 1.009 1.007 1.005
1.028 1.027 1.026 1.025 1.024 1.022 1.020 1.018 1.016 1.014 1.012
1.036 1.035 1.034 1.033 1.031 1.029 1.027 1.025 1.023 1.021 1.019
1.045 1.044 1.043 1.042 1.040 1.038 1.036 1.034 1.031 1.028 1.025
1.053 1.051 1.051 1.049 1.047 1.045 1.043 1.041 1.038 1.035 1.032
1.063 1.062 1.060 1.058 1.056 1.054 1.052 1.049 1.046 1.043 1.040
1.072 1.070 1.068 1.066 1.064 1.062 1.059 1.056 1.053 1.050 1.047
1.080 1.078 1.076 1.074 1.072 1.069 1.056 1.063 1.062 1.057 1.054
1.086 1.084 1.082 1.080 1.077 1.074 1.071 1.068 1.065 1.062 1.059
1.095 1.093 1.091 1.088 1.085 1.082 1.079 1.076 1.073 1.070 1.067
1.100 1.098 1.095 1.092 1.089 1.086 1.083 1.080 1.077 1.074 1.071
Mixing Rate KYMCO SIGMA Coolant Concentrate Distilled Water
20%
30%
40%
50%
55%
0.9±0.15kg/cm_
80±2
90
3.5
4.5mm
Total system 1400±20cc Radiator: 1000±20cc
15
20
25
30
425cc
PEOPL E 250
Reserve tank: 400±20cc
35
40
45
50
975cc

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents