16
. BATTERY/CHARGING SYSTEM
SPECIAL TOOLS
Flywheel holder
Flywheel puller
TROUBLESHOOTING
No power
• Dead battery
• Disconnected battery cable
• Fuse burned out
• Faulty ignition switch
Low power
• Weak battery
• Loose battery connection
• Charging system failure
• Faulty regulator/rectifier
16-3
E021
E003
Intermittent power
• Loose battery cable connection
• Loose charging system connection
• Loose connection or short circuit in
ignition system
Charging system failure
• Loose, broken or shorted wire or connector
• Faulty regulator/rectifier
• Faulty A.C. generator