Matchcode Serial Commands

Matchcode Type
Number of Master Symbols
New Master Pin
Enter Master Symbol Data
Request Master Symbol Data
Delete Master Symbol Data
Match Replace
Mismatch Replace
MS-4X Imager User's Manual
<K223,matchcode type,sequential matching,match start
position,match length,wild card character,sequence on
No Read,sequence on mismatch>
<K224,number of master symbols>
<K225,status>
<K231,master symbol number,master symbol data>
<K231?,>[for all] or <K231?,master symbol number>
<K231,master symbol number,>
<K735,status,match replacement string>
<K736,status,mismatch replacement string>
Matchcode
9-3