Read Next Symbol as Master Symbol

Definition:
After you've set the size in the database, you can order the imager to read
the next symbol as the master symbol for any given master symbol number.
Serial Cmd:
<Gmaster symbol
To store the next symbol decoded as master symbol # 1, send:
<G>
To store the next symbol decoded as the master symbol for any other
master symbol database number, send:
<Gmaster symbol number
For example,
symbol # 5.
ESP:
In the Master Database tab under the Output Format menu,
1. Select the master symbol index number in which you want to store the
symbol data.
2. Click the Read Symbol into Selected Index button.
Caution: If you've selected an index which already has existing data, that
data will be copied over by new decoded data when you use this command.

Request New Master Status

Usage:
Informs the user when a new master symbol is pending and which position
it is in.
Definition:
Returns the position in the master symbol database that will be loaded on
the next read.
Serial Cmd:
<NEWM>
The imager returns: <NEWM/next master to load>
Once a symbol has been read and loaded, the status will be cleared and the
response will be <NEWM/0>.
(See also
New Master Pin
13-14
number>
or <G1>.
<G5>
will cause the next symbol read to be entered as master
in Matchcode.)
[1-10]>.