Communication Protocol Commands
Micro QR Code
Postal Symbologies
Code 39
Codabar
Interleaved 2 of 5
UPC/EAN
Code 128/EAN 128
Code 93
PDF417
Pharmacode
Data Matrix
QR Code
BC412
DataBar-14 (RSS-14)
DataBar Limited (RSS Limited)
DataBar Expanded (RSS Expanded)
MicroPDF417
I/O Parameters
Power On/Reset Counts
Time Since Reset
Service Message
Serial Verification
Beeper
Quality Output
Symbol Data Output
No Read Message
Frame Information
LED Configuration
A-10
<K459,status>
<K460,postal symbology type,POSTNET status,PLANET status,
USPS4CB status,POSTNET allow B and B' fields,Australia Post
allow 0 FCC>
<K470,status,check character status,check character output status,
large intercharacter gap,fixed symbol length status,fixed symbol
length,full ASCII set>
<K471,status,start/stop match,start/stop output,large intercharacter
gap,fixed symbol length status,symbol length,check character
type,check character output>
<K472,status,check character status,check character output status,
symbol length #1, symbol length #2, guard bar status,range mode
status>
<K473,UPC status,EAN status,supplemental status,separator status,
separator character,supplemental type,format UPC-E as UPC-A>
<K474,status,fixed symbol length status,fixed symbol
length,EAN 128 status,output format,application record separator
status,application record separator character,application record
brackets,application record padding>
<K475,status,fixed symbol length status,symbol length>
<K476,status,[unused],fixed symbol length status,fixed symbol
length>
<K477,status,fixed bar count status,fixed bar count,minimum bar
count,bar width mode,direction,fixed threshold value>
<K479,ECC 200 status, ECC 000 status,ECC 050 status, ECC
080 status,ECC 100 status,ECC 140 status,ECC 120 status,ECC
130 status>
<K480,status>
<K481,status,check character output,fixed symbol length status,
fixed symbol length>
<K482,status>
<K483,status>
<K484,status,fixed symbol length status,fixed symbol length>
<K485,status,[unused],fixed symbol length status,fixed symbol
length>
<K406,power-on,resets,power-on saves,power-on flash saves>
<K407,hours,minutes>
<K409,status,service message,threshold,resolution>
<K701,serial command echo status,serial command beep status,
control/hex output>
<K702,status>
<K704,quality output separator,decodes per trigger status>
<K705,symbol data output status,when to output>
<K714,status,message>
<K734,output frame number,output coordinates>
<K737,LED mode,ISO/IEC 16022 grade>