Output on Axial Non-Uniformity
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 to an active state when Axial Non-Uniformity
Threshold is met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth
threshold,output on UEC,UEC threshold>
Default:
Disabled
Options:
0 = Disabled
Output on Unused Error Correction
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 to an active state when UEC Threshold is
met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on
Default:
Disabled
Options:
0 = Disabled
Symbol Contrast Threshold
Usage:
Lets the user set the acceptable level of symbol quality.
Definition:
Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<K800,output on symbol
growth,print growth threshold,output on axial non-uniformity,axial non-uniformity
threshold,output on UEC,UEC threshold>
Default:
Grade C
Options:
0 = Grade A
1 = Grade B
2 = Grade C
3 = Grade D
MS-4X Imager User's Manual
threshold,output on axial
1 = Enabled
UEC,UEC threshold>
1 = Enabled
contrast,symbol contrast
I/O Parameters
non-uniformity,axial non-uniformity
threshold,output on print
7-27