Symbology
Definition:
This field allows the user to configure the database to enable specific symbologies
for selected database indexes. Symbology-specific parameters must be
configured with the appropriate symbology command.
For example, if fixed length Code 128 is required, it must first be set up with
the Code 128 command: <K474>.
To select a particular symbology, add the number value associated with that
symbology.
Examples:
If Data Matrix and Code 39 are required, the paramater would be: 2 + 16 = 18.
If I 2/5, BC412, and DataBar Limited (RSS Limited) are required, the
parameter would be: 128 + 2048 + 16384 = 18560.
Serial Cmd: <K255,index,shutter speed,gain,focal distance,pixel sub-sampling,row
pointer,column pointer,row depth,column width,narrow margins,background
color,symbology>
Default:
Disabled
Disabled
When Symbology is disabled, the database uses the current Symbology setup to
determine active symbologies.
Any Symbology (Add 1)
All symbologies except Pharmacode are enabled while this database index is being
used.
Data Matrix (Add 2)
If enabled, Data Matrix will be active for this database index.
Important: The ECC level must be configured using the Data Matrix command <K479>. If
no ECC level has been configured, the imager will not decode Data Matrix symbols.
QR Code (Add 4)
If enabled, QR Code will be active for this database index.
Code 128 (Add 8)
If enabled, Code 128 will be active for this database index.