Keyboard IN Reports
The host operating system will interpret Keyboard IN Reports from the imager as if the
user were typing keyboard text. The host operating system sends keystrokes to the current
application. This is commonly called a Keyboard Wedge configuration.
There is one type of Keyboard Report used:
Report Type
Keyboard IN (imager to host)
Note: If Keyboard IN Reports is enabled, and Microscan HID IN Reports is disabled,
the read cycle must be Continuous Read 1 Output, because there will be no External
Trigger or Serial Trigger. It is not possible to send commands to the imager as Keyboard
OUT Reports. To send commands to the imager via USB, the host application must
establish a connection with the imager and send Microscan HID OUT Reports.
Serial Cmd:
<K149,Microscan HID IN Report
Default:
0
Options:
0 = Disabled
Keyboard IN Reports Enabled
When this feature is enabled, the imager will send Keyboard IN Reports to the host,
containing data originated by the imager.
Keyboard IN Reports Disabled
When this feature is disabled, the imager will not send Keyboard IN Reports to the host,
containing data originated by the imager.
MS-4X Imager User's Manual
Data Content
Symbol data; No Reads; Service messages
status,Keyboard IN Report
1 = Enabled
Communications
status>
3-25