Image Process Looping
Usage:
Useful in applications where it is necessary to process a single captured
image multiple times using different IP and decode parameters.
Serial Cmd: <K256,switch mode,frame
Default:
Disabled
Options:
0 = Disabled
Disabled
When Image Process Looping is set to Disabled, an image is captured for every database
configuration, whether or not any camera settings have been modified.
Enabled
When Image Process Looping is set to Enabled, the last captured image frame is re-
processed with the new IP and decode parameters. If camera settings have not been
changed from the last capture event, and when a database configuration is loaded to
current, active settings, no new image is captured.
Note: An exception to this is the first database index: a new image is always captured
when the first database index is used. When a camera setting has been modified from one
database setting to the next, a new image is captured. For example, if all database entries
contained the same camera setting values but had different IP and decode parameters, an
image frame would only be captured when the first database configuration was used.
MS-4X Imager User's Manual
count/time,image process
1 = Enabled
Configuration Database
looping,image dimensions>
11-11