Microscan MS-4X User Manual page 159

Imager
Hide thumbs Also See for MS-4X:
Table of Contents

Advertisement

DataBar Limited
Note: DataBar Limited was previously known as "RSS Limited".
Usage:
DataBar Limited is designed to be read by laser and CCD readers. It is
not recommended for omnidirectional slot scanners.
Definition:
Encodes a smaller 14-digit symbol (74 modules wide) that is not omnidirectional.
Serial Cmd:
<K483,status>
Default:
Disabled
Options:
0 = Disabled
DataBar-14
Note: DataBar-14 was previously known as "RSS-14".
Usage:
Used in the grocery, retail, and prescription drug industries where 14-digit
EAN item identification may be needed.
Definition:
DataBar-14 is a fixed symbol length symbology that encodes 14 digits,
including a 1-digit indicator. DataBar-14 is 96 modules wide. It can be
stacked in two rows, it can read omnidirectionally if printed in full height, or
horizontally if height-truncated for small marking.
Serial Cmd:
<K482,status>
Default:
Disabled
Options:
0 = Disabled
MS-4X Imager User's Manual
1 = Enabled
1 = Enabled
Symbologies
6-35

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MS-4X and is the answer not in the manual?

Questions and answers

Table of Contents