2.22.1 Record Log Features
Incoming calls to a PDN or SDN extension.
The PBX waits for a preprogrammed time period between the end of dialling and start of the SMDR timer
for outgoing trunk calls. When the PBX has sent out all dialled digits to the telephone company and this
timer expires, the PBX starts counting the call. A display PT shows the elapsed time of the call. The starting
time and the total duration of the call are recorded on SMDR.
® 10.3 PBX Configuration—[2-3] System—Timers & Counters—Dial / IRNA / Recall / Tone—
Dial—Analogue CO Call Duration Start
If the reverse signal detection has been set (® 2.5.4.5 Reverse Circuit), the PBX will start counting the
call after detecting the reverse signal from the telephone company regardless of the above timer.
Serial Interface (RS-232C) Parameters
The following communication parameters can be assigned for the Serial Interface (RS-232C) port.
a.
New Line Code: Select the code for the PC or printer. If the PC or printer automatically feeds lines
with carriage return, select "CR". If not, select "CR + LF".
® 19.1 PBX Configuration—[11-1] Maintenance—Main—RS-232C—
b.
Baud Rate: A baud rate code indicates the data transmission speed from the PBX to the PC or printer.
® 19.1 PBX Configuration—[11-1] Maintenance—Main—RS-232C—
c.
Word Length: A word length code indicates how many bits compose a character.
® 19.1 PBX Configuration—[11-1] Maintenance—Main—RS-232C—
d.
Parity Bit: A parity code indicates what type of parity is used to detect an error in the string of bits
composing a character. Make an appropriate selection depending on the requirements of the PC or
printer.
® 19.1 PBX Configuration—[11-1] Maintenance—Main—RS-232C—
e.
Stop Bit Length: A stop bit code indicates the end of a bit string which composes a character. Select
an appropriate value depending on the requirements of the PC or printer.
® 19.1 PBX Configuration—[11-1] Maintenance—Main—RS-232C—
If a call is transferred to an ICD group using Automatic Transfer, the condition code "TR" will not be recorded
on SMDR (® 2.12.1 Call Transfer).
[Host PBX Access Code]
The dialled number including the Host PBX Access code will be recorded on SMDR only if the modified
number setting is selected in the ARS setting for SMDR.
When a Host PBX Access code is assigned to a trunk group, calls to extensions of the host PBX are not
recorded on SMDR.
A Host PBX Access Code can be used to record only long distance calls on SMDR when a trunk port is
connected directly to the telephone company (not a host PBX). This is allowed when the long distance
code (e.g., "0") is assigned as the Host PBX Access code. All local calls (e.g., calls that do not require a
"0" to be dialled first) are treated as extensions of the telephone company and do not get recorded on
SMDR, because in this case this PBX recognises the telephone company as the host PBX. Therefore, only
long distance calls are recorded on SMDR.
[Output to a Telnet compatible Terminal Emulator]
In order to activate a connection to a terminal emulator, the IP address of the mother board, port number,
user ID ("SMDR"), and password must be entered.
If a terminal emulator user incorrectly enters the user ID or password 3 times consecutively, an alarm will
be sent and connection will not be possible for 10 minutes.
Through system programming, it is possible to assign the PBX port number and password.
The terminal emulator application must be running constantly. If the application is terminated, call records
that occur after the termination will be recorded in the PBX's memory. However, if the number of call records
exceeds the PBX's capacity, older records will be deleted. Also, when the application restarts or is
reconnected, duplicated call records may be output.
242
Feature Guide
Communication—NL Code
Communication—Baud Rate
Communication—Word Length
Communication—Parity Bit
Communication—Stop Bit