Event Report Codes - Bosch ICP-EZM2 Installer's Manual

Intrusion control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

Easy Series (ICP-EZM2) | Installer Guide | 7.0 Reference Materials
7.4

Event Report Codes

Event
Intrusion Alarm
Intrusion Alarm Verified
Intrusion Alarm Unverified
Intrusion Alarm 24-hr
Intrusion Alarm 24-hr Restoral
Intrusion Alarm Restoral
Duress
Exit Error
Fire Alarm
Fire Alarm Unverified
Fire Alarm Restoral
Panic
Panic Restoral
User Emergency (Medical)
User Fire
User Fire Restoral
User Panic
Cancel
Intrusion Trouble
Intrusion Trouble Restoral
Intrusion Point Bypass
Intrusion Point Bypass Restoral
Fire Trouble
Fire Trouble Restoral
Recent Closing
Close (System On) Unoccupied
Close (System On) Occupied
Close (System On) Custom
Close (System On) Partial
Close (System On) Keyswitch
Open (System Off)
Open (System Off) Keyswitch
AC Fail
AC Fail Restoral
Auto System Test (Normal)
Auto System Test (Off-Normal)
Auxiliary Power Fault
Auxiliary Power Restoral
Communication Fail
Communication Restoral
Control Center Supervision Fail
Control Center Supervision Restoral
Control Center Tamper
Control Center Tamper Restoral
Local Programming
Low Battery
Low Battery Restoral
Communication Test
Phone Line Fault
Phone Line Fault Restoral
60
SIA Report
BA Burglary Alarm
BV Burglary Alarm Verified
BG Unverified Event Burglary
BA Burglary Alarm
BH Burglary Alarm Restore
BR Burglary Restoral
HA Hold Up Alarm
EA Exit Alarm
FA Fire Alarm
FG Unverified Event-Fire
FH Fire Alarm Restore
HA Holdup Alarm
HH Holdup Alarm Restore
QA Emergency Alarm
FA Fire Alarm
FH Fire Alarm Restore
HA Holdup Alarm
BC Burglary Cancel
BT Burglary Trouble
BJ Burglary Trouble Restore
BB Burglary Bypass
BU Burglary Unbypass
FT Fire Trouble
FJ Fire Trouble Restore
CR Recent Closing
CL Closing Report
CL Closing Report
CL Closing Report
CL Closing Report
CS Closing Keyswitch (User 255)
OP Opening Report
OS Opening Keyswitch (User 255)
AT AC Trouble
AR AC Restoral
RP Automatic Test
RY Test Off Normal
IA Equipment Failure Condition
IR Equipment Fail Restoral
YC Communications Fail
YK Communications Restoral
EM Expansion Device Missing
EN Expansion Missing Restore
ES Expansion Device Tamper
EJ Expansion Device Tamper
Restore
LX Local Programming Ended
YT System Battery Trouble
YR System Battery Restoral
RX Manual Test
LT Phone Line Trouble
LR Phone Line Restoral
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Contact ID Report
1 130 Burglary
1 139 Burglary
1 130 Burglary
1 133 24 Hour (Safe)
3 133 Restoral
3 130 Burglary
1 121 Duress
1 374 Exit Error (zone)
1 110 Fire
1 110 Fire
3 110 Fire
1 120 Panic
3 120 Panic
1 101 Personal Emergency
1 110 Fire
3 110 Fire
1 120 Panic
1 406 Cancel
1 380 Sensor Trouble
3 380 Sensor Trouble
1 570 Zone/Sensor bypass
3 570 Zone/Sensor bypass
1 373 Fire Trouble
3 373 Fire Trouble
1 459 Recent Closing
3 401 Unoccupied Arm by User
3 441 Occupied Arm by User
3 441 Custom Arm by User
3 456 Partial Arm by User
3 409 Keyswitch O/C (User 255)
1 401 O/C by User
1 409 Keyswitch O/C (User 255)
1 301 AC Loss
3 301 AC Loss
1 602 Period Test Report (User 0)
1 608 Period Test Report, System Trouble
Present
1 310 Ground Fault
3 310 Ground Fault
1 354 Failure to communicate event
3 354 Failure to communicate event
1 333 Expansion module failure
3 333 Sensor Trouble
1 341 Expansion Device Tamper
3 341 Expansion Device Tamper
1 628 Program mode exit
1 302 Low System Battery
3 302 Low System Battery
1 601 Manual trigger test report