4.0 Programming

4.1

Enter Programming

Select one of the following methods to enter the Installer Menu:
Method
Steps
House Phone
1.
Press [#][#][#].
2.
Listen for the voice prompt to enter a passcode.
3.
Enter the installer passcode.
4.
Press [3] for basic programming, or [4] for expert programming.
Outside Phone
1.
Call the premises phone number.
2.
After the call is answered by either a person or a telephone answering device, press [*][*][*] to
disconnect the answering party and access the system.
If the phone is not answered by a person or telephone answering device, the system answers
after a programmed number of rings. Refer to Expert Programming Item Number 222 on page
42.
3.
Listen for the voice prompt to enter a passcode.
4.
Enter the installer passcode.
5.
Press [3] for basic programming, or [4] for expert programming.
Installer Quick
2
Connect
1.
Connect a phone set to either
the test posts or the phone
terminals.
2.
Press and hold the System
Test button for approximately
15 sec.
3.
Listen for the voice prompt to enter a passcode.
4.
Enter the installer passcode.
5.
Press [3] for basic programming, or [4] for expert programming.
RPS
Refer to Section 4.6 Remote Programming Software (RPS) on page 55 for more information.
1
If the passcode length = four digits, the default installer passcode is 5432. If the passcode length = six digits, the default
installer passcode is 543211. Refer to Section 4.3.8 User Programming Items on page 53 to change the passcode
length and the installer passcode.
2
Select the installer quick connect method if a phone line is not available, or a local connection is required. The system
must be off to use this method.
First Time Programming
1. Set the country code to the appropriate code for your installation before making any other
programming changes.
This selection sets control panel's defaults to the appropriate country-specific values. Refer to
Section 4.2.4 Country Code on page 34.
2. Set the time and date. Refer to Section 1.5 Installer Phone Menu on page 6.