Bosch ICP-EZM2 Installer's Manual page 39

Intrusion control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

.
Item
Programming Item
Number
Swinger Bypass
131
Count
Auto Protection Level
132
System On Order
133
Options
Cross Zone Timer
134
Restricted Alarm
136
Memory
137
Latching Point and
Enclosure Tamper
Latching System
138
Device Tamper
Verbose System Test
139
Enabled
Demo Mode
140
Restrict Installer
142
Passcode
Default
= Country-specific default. Select this programming item to hear the updated default value.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Easy Series (ICP-EZM2) | Installer Guide | 4.0 Programming
Description (Range)
1 = One alarm report allowed from point while system is on before point
is bypassed.
2 = Two alarm reports allowed from point while system is on before point
is bypassed.
3 = Three alarm reports allowed from point while system is on before
point is bypassed.
0 = System always turns on (unoccupied) when selected.
1 = System only turns on (unoccupied) if a perimeter point is faulted
during Exit Delay. If no point is faulted, the system turns on
(occupied).
Determines the order that system-on options are announced to the user.
1
2
1 = "Stay
," "Leave
," "Custom
2 = "Stay," "Custom," "Leave"
3 = "Leave," "Stay," "Custom"
4 = "Leave," "Custom," "Stay"
5 = "Custom," "Leave," "Stay"
6 = "Custom," "Stay," "Leave"
1
"Stay" = System On Occupied
2
"Leave" = System On Unoccupied
3
"Custom": Only announced if points are programmed as Custom
Protection points. Refer to Section 4.2.1 Point Programming Items on
page 46 to assign Custom Protection points.
Enter how long the system waits for at least two Cross Zone points to be
faulted before the control panel sends a Verified Alarm report to the
central station (60 to 3600 sec).
If only one Cross Zone point is faulted during this time, the control panel
sends an Unverified Alarm report to the central station.
The cross zone timer is also used as the confirmed alarm timer.
0 = Any user can clear the alarm memory.
1 = Only the master user can clear the alarm memory.
0 = Any user token or passcode can clear a point or enclosure tamper
condition.
1 = Only the installer passcode can clear a point or enclosure tamper
condition.
0 = Any user token or passcode can clear a tamper condition from a
system device (control center, DX2010, or wireless hub).
1 = Only the installer passcode can clear a tamper condition from a
system device.
0 = Internal tests are conducted silently, and the control center
announces the entire test status when all tests are complete.
1 = The control center announces tests as they are performed.
0 = The system only announces all telephone menu messages over the
phone.
1 = The system announces all telephone menu messages over the
phone and at all control centers connected to the system.
0 = Master user passcode or token not needed to enable Installer
Passcode.
1 = Master user must present token or enter passcode before installer
enters Installer Passcode. Installer passcode is enabled until a user
turns the system on.
The master user can also enable installer access from the User
Phone Menu ([3] System Maintenance → [6] Expert Programming).
Refer to page 7 for more information. This setting also restricts the
availability of certain Installer Menu options.
3
"
Entry
1
1
1
120
0
0
0
1
0
0
39