2.11.2 Plug-In Power Supply; 2.11.3 12 Vdc Standby Battery - Bosch ICP-EZM2 Installer's Manual

Intrusion control panel
Hide thumbs Also See for ICP-EZM2:
Table of Contents

Advertisement

.

2.11.2 Plug-in Power Supply

1. Connect a ground wire from the enclosure to a good
earth ground source.
2. Connect the enclosure ground wire.
For instructions, refer to Steps 5 to 8 in Section 2.11.1
EZPS Wire-in Power Supply on page 19.
3. Connect the plug-in power supply to the control panel
board.

2.11.3 12 VDC Standby Battery

When all system wiring is complete, apply AC and standby
battery power to the control panel.
Bosch Security Systems, Inc. | 5/07 | F01U025147-01
Easy Series (ICP-EZM2) | Installer Guide | 2.0 Installation
3
2
1
(+)
(-)
12 VDC