3.2.6 G3-2/3 SWITCHES

These switches require an optional G3 interface unit.
G3-3 switches are the same as for G3-2 switches.
G3-2 Switch 00
No
FUNCTION
0-1
Monitor speaker during
communication (tx and rx)
Bit 1
Bit 0
Setting
0
0
Disabled
0
1
Up to Phase B
1
0
All the time
1
1
Not used
2
Monitor speaker during
memory transmission
0: Disabled 1: Enabled
3-7
Not used
G3-2 Switch 01
No
FUNCTION
0-3
Not used
4
DIS frame length
0: 10 bytes 1: 4 bytes
5
Not used
6
Forbid CED/AMsam output
0: Off
1: On (Forbid output)
7
Not used
SM
CÓPIA NÃO CONTROLADA
(0, 0): The monitor speaker is disabled all through
the communication.
(0, 1): The monitor speaker is on up to phase B in
the T.30 protocol.
(1, 0): Used for testing. The monitor speaker is on
all through the communication. Make sure that you
reset these bits after testing.
1: The monitor speaker is enabled during memory
transmission.
Do not change the settings.
Do not change the settings.
1: The bytes in the DIS frame after the 4th byte will
not be transmitted (set to 1 if there are
communication problems with PC-based faxes
which cannot receive the extended DIS frames).
Do not change the setting.
Do not change this setting, unless the
communication problem is caused by a CED or
ANSam transmission.
Do not change the setting.
73
CÓPIA NÃO CONTROLADA
BIT SWITCHES
SP No. 1-106-001
COMMENTS
SP No. 1-106-002
COMMENTS