SERVICE PROGRAM MODE TABLES
5816 208
Error Code
Displays a number that describes the error code that was issued when either
SP5816 204 or SP5816 207 was executed.
Cause
Illegal Modem Parameter
Operation Error, Incorrect
Setting
Error Caused by
Response from GW URL
5816 250
CommLog Print
Prints the communication log.
5821*
Remote Service Address (Japan Only)
5821 1*
CSS PI Device Code
5821 2*
RCG IP Address
5824
NVRAM Data Upload
Uploads the UP and SP mode data (except for counters and the serial number)
from NVRAM on the control board to a flash memory card.
While using this SP mode, always keep the front cover open. This prevents a
software module accessing the NVRAM during the upload.
5825
NVRAM Data Download
Downloads the content of a flash memory card to the NVRAM on the control
board.
B291/B295/B296/B297
CÓPIA NÃO CONTROLADA
Code
Meaning
-11001
Chat parameter error
-11002
Chat execution error
-11003
Unexpected error
-12002
Inquiry, registration attempted without
acquiring device status.
-12003
Attempted registration without execution of
an inquiry and no previous registration.
-12004
Attempted setting with illegal entries for
certification and ID2.
-2385
Attempted dial up overseas without the
correct international prefix for the telephone
number.
-2387
Not supported at the Service Center
-2389
Database out of service
-2390
Program out of service
-2391
Two registrations for same device
-2392
Parameter error
-2393
Basil not managed
-2394
Device not managed
-2395
Box ID for Basil is illegal
-2396
Device ID for Basil is illegal
-2397
Incorrect ID2 format
-2398
Incorrect request number format
Sets the PI device code. After changing this
setting, you must switch the machine off and on.
Sets the IP address of the RCG (Remote
Communication Gate) destination for call
processing at the remote service center.
[00000000h ~ FFFFFFFFh/ 00000000h /