Table C-1 (continued)
Error Message
Failure Area/Possible Solution
-5.2VDC HIGH
Same as above.
WARNING
-5.2VDC LOW
Same as above.
WARNING
-12VDC HIGH
Same as above.
WARNING
-12VDC LOW
Same as above.
WARNING
48VDC HIGH
Same as above.
WARNING
48 VDC LOW
Same as above.
WARNING
POWER CYCLE
The System Controller receives a command to perform a
power-off, followed by a power-on, from the System
Controller serial port.
System Events - Delayed Power-off
Table C-2
Error Message
AMBIENT OVER TEMP The System Controller detects an over-temperature
BLOWER A FAILURE
BLOWER B FAILURE
BLOWER FAILURE
System Events - Immediate Power-off
Failure Area/Possible Solution
condition. An alarm is sent to the CPU, five seconds later
the System Controller initiates the power-off sequence.
The System Controller detects a fan problem. An alarm is
sent to the CPU, five seconds later the System Controller
initiates the power-off sequence (rackmount systems
only).
Same as above (rackmount systems only).
Same as above (deskside systems only).