Table C-4 (continued)
Error Message
STACK FAULT PID 0–6
TEMP SENSOR FAILURE
TIMER IN COMP 1
TIMER OUT COMP 1–5
XMITTER 1 TIMEOUT
XMITTER 2 TIMEOUT
Internal System Controller Error Messages
Error Meaning
One of the seven stack areas used by a System
Controller process overflowed its assigned
boundaries.
The System Controller detected an invalid
measurement from the temperature sensor.
The timer input compare port received an interrupt.
The port is not used and the interrupt is treated as an
error.
One of the five timer output compare ports received
an interrupt. The port is not supported and the
interrupt is treated as an error.
The System Controller's 1st UART experienced a
failure.
The System Controller's 2nd UART experienced a
failure.