Appendix C: System Controller Messages
116
Table C-2 (continued)
Error Message
BLOWER A RPM FAIL
BLOWER B RPM FAIL
BLOWER RPM
FAILURE
TEMP SENSOR
FAILURE
FP BUTTON STUCK
System Events - Informative
Table C-3
Error Message
SYSTEM ON
SYSTEM OFF
SYSTEM RESET
NMI
SCLR DETECTED
System Events - Delayed Power-off
Failure Area/Possible Solution
The System Controller detects a fan not at speed. An
alarm is sent to the CPU, five seconds later the System
Controller initiates the power-off sequence (rackmount
systems only).
Same as above (rackmount systems only).
Same as above (deskside systems only).
The System Controller detects a temperature sensor with
a reading so far out of range that the sensor is assumed
to have failed. The condition i s logged but no power-off
sequence is initiated.
The System Controller detects a status panel button stuck
in the depressed position. After a 30-second wait, the
power-off sequence is initiated (the depressed button
interferes with the System Controller's normal
monitoring operation.
Error Meaning
The System Controller reports the power-on sequence
completed
The System Controller reports the power-off sequence
completed
The System Controller generates a backplane reset, due
to menu selection or serial port request.
The System Controller generates a backplane NMI, due
to menu selection.
The System Controller detects a backplane reset, then
initiates the bootmaster arbitration process.