Section 2: Installation and Setup
PIB Faceplate Connections
• 10Base-T/100Base-TX Ethernet: Connects the cinema projector to a network.
• GPIO: Connects the cinema projector to external input and output devices, such as the Christie ACT. See
Connecting Devices to the GPIO Port
• SCCI: A Simple Contact Closure Interface (SCCI) port that uses a simple dry contact closure to turn the
lamp on or off or open or close the douser. See
• RS232 ICP: For direct DLP communication. Trained users required.
• RS232 PIB: Connects the cinema projector to Christie accessories or third-party automation equipment.
• 3D: Connect a variety of 3D products to this connector, such as MasterImage or Real D for polarizing and
de-ghosting 3D content during projection.
• Marriage: Allows the cinema projector to display encrypted content.
• Emergency Start: Starts the cinema projector, turns the lamp on, and opens the douser when the Touch
Panel Controller is unavailable or disconnected. Press and hold this button, to close the douser and turn the
lamp off; the power remains on.
• Reset: Resets the cinema projector electronics. If the cinema projector is in standby mode, it returns to
standby mode after the reset. If the cinema projector is in any other state, the cinema projector is on and the
lamp is off following the reset.
• DVI-A / DVI-B: These are single-link ports for single-link cables and connectors. The connectors can be
used together as a twin-link DVI port.
• HD-SDI A/HD-SDI-B: Connects the cinema projector to high-definition cinema sources. The connectors
can be used together to deliver Dual Link HD-SDI following the SMPTE 372M standard.
PIB Faceplate Status Indicators
• STBY: Standby power (Single Color Green) indicates the presence of +24V from the standby power supply.
• OFF: Indicates no standby power (breaker OFF or Standby power failure).
• Green: Indicates standby power.
• PWR: Main power (Single Color Green) indicates the presence of +24V from the Low Voltage Power
Supply (LVPS).
• OFF: No LVPS power (STANDBY mode or breaker OFF).
• Green: Indicates full power.
• RUN: Blinking heartbeat (bi-color green/yellow).
• OFF or Solid Green: Indicates cinema projector not functioning properly.
• Blinking Green: OK (software/communication/OS/ICP/Enigma/IMB if present are operating
normally).
• Solid Yellow: Communication error. NiOS functioning OK, but can no longer communicate with TPC.
• PIB: cinema projector Intelligence Board Status (Bi-color Red/Green)
• OFF: Not detected.
• Red: Detected communication problems etc.
• Blinking Red: PIB card seating error.
• Green: Detected and working properly.
• ICP: Integrated Cinema Processor Status (Bi-color Red/Green)
• OFF: Not detected.
• Red: Detected communication problems etc.
• Green: Detected and working properly.