Quick Start Instructions - Pro Spot PHS-101 Instruction Manual

Hybrid spot welder
Hide thumbs Also See for PHS-101:
Table of Contents

Advertisement

2.0

Quick Start Instructions

Set-up:
1. Connect compressed air no greater than 135 psi to the air inlet located on the back panel.
2. Adjust the regulator knob until the pressure gauge reads 90 psi.
Turn Welder On/O
1. To Turn On: Press Weld Control Button
2. To Turn O : Unplug Welder, Press and Hold Weld Control Button
Welding
1. Rotate the Weld Control button until the cursor points to Weld Time.
2. Press the Weld Control button then rotate it to adjust the Weld Time. For double-sided welding,
adjust Weld Time to 260-300 and, for single-sided welding, adjust Weld Time to 120.
3. Press the Weld Control button to commit the change.
4. Repeat steps 1-3 to set your Weld Power. For double-sided welding, adjust Weld Power to Medium or
High and, for single-sided welding, adjust weld power to Low or Medium.
5. Place the welding gun at the weld area then press and hold the lower trigger to weld. Press the upper
trigger to spread the electrodes open for better access.
Charging
1. Plug the power cord in to either 120VAC or 240VAC single phase power to initiate the charge cycle.
If the power cord is already plugged in, the charge cycle will begin after a minute of no welding.
2. Unplug the power cord or weld to interrupt the charge cycle.
System Display.
Shows battery voltage and charge current.
Weld Control
Button
Turn Welder On/Off
To Turn On : Press Weld
Control Button
To Turn Off : Unplug
Welder Press + Hold
Weld Control Button
INTRODUCTION
WELD TIME:
180 mS
WELD POWER: LOW
COOLING:
OFF
System Menu
READY
All Info Copyright © Pro Spot International Inc.
Air Pressure
Air Pressure
Regulator
9

Hide quick links:

Advertisement

Table of Contents
loading