Quick Start Instructions - Pro Spot PR-2000 Instruction Manual

High frequency inverter resistance spot welder
Table of Contents

Advertisement

PR-2000

Quick start instructions

Figure 1.1
Figure 1.2
Copyright © Pro Spot International, Inc. 2005-2009
WARNING! Before turning the welder on, make sure it is connected
to proper electricity by certified people. Connect air to the air inlet on
back panel.
1. Turn the Power Switch on the front panel ON.
2. Connect Air to the air inlet located on the back panel.
3. During the test procedure a "Push Help to change language" prompt appears
on the display screen . Click the Help button to acces the System settings screen
where the language can be changed. Select desired language by clicking the
"Change Language" button, then exit.
4. After test procedure, the software defaults to HSS/Galv. Two Sided weld mode.
5. The welder is now ready to operate. Make sure air pressure is set at 90 PSI.
Place the welding gun at the weld area and press the lower trigger button to weld.
The upper weld button is for spreading the electrodes open for better access.
6. There are 6 different power levels pre-programmed into the PR-2000. The soft-
ware defaults to 0.7mm weld program. That is the thickness of one of the two lay-
ers of metal you are welding . To chage between pre-set power settings press
Navigation button, Up (fig. 1.1). The programs will switch between 0.7, 1.0, 1.2,
1.5, 2.0 and 2.5mm.
7. To go to the next weld mode: "Mild Steel" press the Navigation button, Right
(fig. 1.2). The same weld power levels are available in each weld mode. Navigate
with the Right and Left arrow buttons and select weld power with the "Next
Program" button (Navigation button, Up).
8. Press the "Help" button anytime for instructions.
Page 3