5.0
DOUBLE-SIDED WELDING

5.3 PS-500 Electrode Alignment

Use the set screws (A, B, C) to align the electrodes. Ex: to move electrode down, loosent screw (C) and
tighten screws (A and B).
Figure 5.5 Electrode Alignment
CORRECT
WRONG
IMPORTANT! Always maintain proper electrode alignment. Not doing so may result in weak, sub-
standard welds!
IMPORTANT! Toujours maintenir l'alignement des électrodes appropriées. Ne pas le faire peut conduire
aux aoudures faibles de qualité inférieure!