CHAPTER 4 Installation of Operating System and bundled software

4.4 Procedures to install Windows into internal HDD/SSD

6.
Dump area is set.
Confirm that there is sufficient free space on the hard disk before acquiring the memory damp.
For details, see "11.4.3 Settings of dump environment (Windows)" of PRIMEQUEST 2000 series Administration
Manual (CA92344-0537).
7.
The management information and configuration information are stored.
For details, see
8.
UPS battery monitor is set.
When the duration of life of the UPS battery is monitored: see "Setting for component replacement alert for
PRIMEQUEST ". This document is downloaded from the following URL.
http://www.fujitsu.com/global/products/computing/servers/mission-
critical/primequest/documents/manuals/
9.
Watchdog Timer allows reboot OS in case that OS freezes. R
passes,
For details, see "8.4 Automatic Partition Restart Conditions" of PRIMEQUEST 2000 series Administration
Manual (CA92344-0537).

4.3.5 Connection of SAN and the internal HDD/SDD after installation

For SAN and the internal HDD/SDD connection after the completion of installation, see PRIMEQUEST 2000 Series SAN
Boot Environment Configuration Manual (C122-E206EN) .
1.
Change and confirm the settings of the detailed information of the FC card.
For details, see PRIMEQUEST 2000 Series SAN Boot Environment Configuration Manual (C122-E206EN).
2.
OneCommand Manager is started. The following driver parameters are set.
For the details of the set value, see San storage device manual.
- Topology
- Queue Depth
- Queue Target
- Link Speed
3.
Check the registry information.
For details on the checking method, see PRIMEQUEST 2000 Series SAN Boot Environment Creation Manual
(C122-E206EN).
For details on setting value, see Manual of SAN storage device.
-TimeOutValue
4.4
Procedures to install Windows into internal HDD/SSD
This section briefly describes the procedures by which Windows is installed in the internal HDD/SSD. Start the installation
after checking the MMB configuration and successful to log in to the MMB.

4.4.1 Presetting

If necessary, the following settings are done.
1.
Remove each built-in HDD that is not the installation destination.
2.
The setting of partition is checked by MMB.
-
Setting of configuration of SB/IOU
See
"3.4.1 Setting the partition
-
Setting of Console Redirection
See
"3.4.6 Settings of Console
-
Video redirection: Enable
-
Virtual media: Enable
-
Setting of various modes
See
"3.4.5 Various mode
3.
[PCI ROM Priority] of BIOS is set.
"5.7 Saving management and configuration
configuration"
Redirection"
settings"
information".
ebooting OS is executed when the set time
65