CHAPTER 4 Installation of Operating System and bundled software
4.4 Procedures to install Windows into internal HDD/SSD
http://support.ts.fujitsu.com/
Note
Driver/Utility can be used by the PRIMEQUEST 2000 series though PRIMERGY is described in the
downloaded binary.
b.
The downloaded file is executed by a double click.
The prompt window of cmd.exe (black window) is displayed for a while and the file is extracted.
c.
The window closes automatically after the extraction is completed.
The download file is extracted and folder or file is newly created.
Remark
If the window does not close even if "Complete" is displayed on the title bar of the window then click the "Close"
button and close the window.
d.
Double click and execute "QConvergeConsole_Installer_Windows_XXXXX.exe" in "QCC_vXXXXXX" directory
created by extraction.
Remark
"XXXX" shows the version number. Read properly.
3.
When the installation is completed, reboot the partition.
4.
Check the setting of management LAN.
The STP function of the port to be connected is turned OFF when the management LAN is used for communication
with MMB in the switching hub which supports the STP function.
5.
Set the trap destination and Mail Sending destination through MMB.
Execute linkage with the operation management software only if necessary.
a.
The [SNMP setting] is displayed on the MMB screen, and enable the SNMP.
b.
The trap destination of SNMP is set through MMB.
See
"6.5.2 Set up of
6.
Set the dump area.
Check whether there is sufficient free space in the hard disk before acquiring the memory dump. For details, see
("11.4.4 Setting (Windows) of dump environment" of PRIMEQUEST 2000 series Administration Manual (CA92344-
0537).
7.
Save the management information and configuration information.
For details, see
8.
UPS battery monitor is set.
When the duration of life of the UPS battery is monitored: see "Setting for component replacement alert for
PRIMEQUEST ". This document is downloaded from the following URL.
http://www.fujitsu.com/global/products/computing/servers/mission-
critical/primequest/documents/manuals/
9.
Watchdog Timer allows reboot OS in case that OS freezes.
passes,
For details, see "8.4 Automatic Partition Restart Conditions" of PRIMEQUEST 2000 series Administration
Manual (CA92344-0537).

4.4.5 After Installation, Connection between SAN and internal HDD/SSD

For SAN and the internal HDD/SDD connection after the completion of installation, see PRIMEQUEST 2000 Series SAN
Boot Environment Configuration Manual (C122-E206EN) .
1.
Change and confirm the settings of the detailed information of the FC card.
For details, see PRIMEQUEST 2000 Series SAN Boot Environment Configuration Manual (C122-E206EN).
2.
OneCommand Manager is started. The following driver parameters are set.
For the details of the set value, see San storage device manual.
- Topology
- Queue Depth
- Queue Target
- Link Speed
3.
Check the registry information.
For details on the checking method, see PRIMEQUEST 2000 Series SAN Boot Environment Creation Manual
(C122-E206EN).
For details on setting value, see Manual of SAN storage device.
-TimeOutValue
SNMP"
"5.7 Saving management and configuration
information".
Rebooting OS is executed when the set time